Elevator control cabinet




Functional characteristics
Comprehensive Protection and Silent Comfort
1)Equipped with multiple layers of safety protection, supporting STO, SBC,and electronic sealing, it achieves the highest safety integrity level in the industry (SIL3)
2)It abandons mechanical contacts that are prone to wear and failure, offering a smaller size, lower noise, and faster response
Precise Control and Intelligent Efficiency
1)Equipped with a high-performance microprocessor and leading control algorithms, it achieves precise control,intelligent scheduling, and optimized energy efficiency
2)In conjunction with platform of remote monitoring, it realizes functions such as fault warning, remote diagnostics, on-demand maintenance, and paperless maintenance
Lean Integration and Easy Installation and Maintenance
1)The drive and control are integrated into one unit, with a compact structure that significantly reduces wiring complexity
2)The modular design facilitates easy installation, upgrades, and maintenance
Exclusive Customization and Flexible Compatibility
1)It supports a high degree of specialized customization to meet customers' individual and phased needs
2)The universal interface design ensures seamless integration with existing elevator equipment and management systems
Specification
| Comparison Dimension | CLCTE1000 | CLCTE2000 | CLCTE3000 |
|---|---|---|---|
| Safety Architecture | Traditional Contactor | STO + SBC Solution | STO + SBC + Safety Bus |
| Response Speed | 50-200ms Mechanical Action | <1ms STO Hardware Cut-off | <1ms STO Cut-off + <5ms Bus Transmission |
| Brake Control | On/Off Control, No Status Monitoring | Communication-based Brake Power Supply, Zero-current Cut-off | SBC Dynamic Braking, Real-time Torque Monitoring, Bus-coordinated Predictive Braking |
| Volume | Many Components, Large Footprint | Modular Design, Reduced >30% | Modular, Reduced >50% |
| Wiring Complexity | Point-to-point Hardwiring, Complex Wiring | Modular Wiring, Medium Complexity | Safety Bus Topology, 50% Reduction in Trailing Cables, Low Complexity |
| Noise | Loud Contactor Engagement Noise | ≤50dB, Silent and Comfortable | ≤50dB, Silent and Comfortable |
| Fault Diagnosis | Manual Troubleshooting, Difficult to Locate | Manual Troubleshooting, Complex to Locate | Segmented Safety and Door Lock Detection, Easy Diagnosis |
| Safety Certification | SIL 2 | SIL 3 | SIL 3 |
| Data Recording & Traceability | Basic Fault Recording | Basic Fault Recording + Cloud Storage | Fault Recording + Full Lifecycle Cloud Data |
| Commissioning Time | Hardwiring Testing, Time-consuming | Quick Short-circuit Testing, Moderate Time | Software Quick Testing, Shorter Time |
| Total Cost of Ownership | Frequent Maintenance, More Downtime, High Cost | Less Maintenance, Still Requires Manual Inspection, Moderate Cost | Predictive Maintenance, 90% Reduction in Unplanned Downtime, Low Cost |
| Intelligence Level | Mechanical Control | Electronic Safety | Digital + Connected Smart Safety Ecosystem |




